EDIFACT Standards to XML component
The EDIFACT Standards to XML component converts UN/EDIFACT messages into XML with less strict ruling. By converting EDIFACT messages into XML, these messages can be processed using other components available in Dovetail like the XLST component.
Supported standards
APERAC_D96BDESADV_D93ADESADV_D96AIFCSUM_D08AIFTFCC_D00BIFTMBC_D98AIFTMBC_D96BIFTMBF_D08AIFTMBF_D95BIFTMIN_D96AIFTMIN_D96A_UTF_8IFTMIN_D98AIFTMIN_D99AIFTMIN_D99BORDERS_D93A
Differences with EDIFACT to XML component
This component works with transformations that are imported from custom mappings made in Altova Mapforce. They are supplied by a particular customer, but we make them available for everyone with their permission. In general these transformations are less strict and produce a different XML compared to the EDIFACT to XML component.
Example
Example for the IFTMIN D96A standard to XML transformation.
- Edifact Input
- XML Output
UNA:+.? '
UNB+UNOA:2+8714252014808::14+8714252011517::14+130402:1219+24535'
UNH+24546+IFTMIN:D:96A:UN'
BGM+340+347605+9'
DTM+137:20130402:102'
DTM+2:20130404:102'
DTM+200:20130403:102'
TSR+11++N'
FTX+DEL+++EXACT DONDERDAG 4.4 TUSSEN 8.15-12.00 UUR:AFLEVEREN'
TOD+6++CIP'
NAD+DP+++DUMMY B.V.+VERLENGDE VOORBEELDWEG 123+AMSTERDAM++1234AB+670'
NAD+CZ+++DUMMY WIRE & CABLE B.V.+INDUSTRIEGEBIED?: 1234:VOORBEELDWEG 10+AMSTERDAM++1234 AB+670'
CTA+IC+:JANE DOE'
COM+?+31(0)12 3456789:TE'
NAD+SF+++DUMMY WIRE & CABLE B.V.+INDUSTRIEGEBIED?: 1234:VOORBEELDWEG 10+AMSTERDAM++1234 AB+670'
CTA+IC+:JANE DOE'
COM+?+31(0)12 3456789:TE'
NAD+FW+++LOGISTICS B.V.++++1234 AB+670'
GID+1.0+1.0:E827::9'
HAN+UST::9'
MEA+AAE+G+KGM:24.0'
MEA+AAE+GMC+MTQ:80.0'
DIM+1+MTR:41.0:41.0:48.0'
PCI+33E'
GIN+BJ+00387142520086154710'
UNT+98126+24546'
UNZ+1+24535'
<?xml version="1.0"?>
<Envelope xmlns="http://www.blujaysolutions.com/2017/IFTMIN"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.blujaysolutions.com/2017/IFTMIN file:///C:/Users/jss/Documents/seacon/germany_interfaces/develop/iftmin_D96A/IFTMIN_D96A.xsd">
<Interchange>
<UNB>
<F0020>24535</F0020>
<S001>
<F0001>UNOA</F0001>
<F0002>2</F0002>
</S001>
<S002>
<F0004>8714252014808</F0004>
<F0008>14</F0008>
</S002>
<S003>
<F0010>8714252011517</F0010>
<F0014>14</F0014>
</S003>
<S004>
<F0017>130402</F0017>
<F0019>1219</F0019>
</S004>
</UNB>
<UNZ>
<F0036>1</F0036>
<F0020>24535</F0020>
</UNZ>
<Group>
<Message_IFTMIN>
<UNH>
<F0062>24546</F0062>
<S009>
<F0065>IFTMIN</F0065>
<F0052>D</F0052>
<F0054>96A</F0054>
<F0051>UN</F0051>
</S009>
</UNH>
<BGM>
<F1004>347605</F1004>
<F1225>9</F1225>
<C002>
<F1001>340</F1001>
</C002>
</BGM>
<DTM>
<C507>
<F2005>137</F2005>
<F2380>20130402</F2380>
<F2379>102</F2379>
</C507>
</DTM>
<DTM>
<C507>
<F2005>2</F2005>
<F2380>20130404</F2380>
<F2379>102</F2379>
</C507>
</DTM>
<DTM>
<C507>
<F2005>200</F2005>
<F2380>20130403</F2380>
<F2379>102</F2379>
</C507>
</DTM>
<TSR>
<C536>
<F4065>11</F4065>
</C536>
<C537>
<F4219>N</F4219>
</C537>
</TSR>
<FTX>
<F4451>DEL</F4451>
<C108>
<F4440>EXACT DONDERDAG 4.4 TUSSEN 8.15-12.00 UUR</F4440>
<F4440>AFLEVEREN</F4440>
</C108>
</FTX>
<UNT>
<F0074>98126</F0074>
<F0062>24546</F0062>
</UNT>
<SG2>
<TOD>
<F4055>6</F4055>
<C100>
<F4053>CIP</F4053>
</C100>
</TOD>
</SG2>
<SG11>
<NAD>
<F3035>DP</F3035>
<F3164>AMSTERDAM</F3164>
<F3251>1234AB</F3251>
<F3207>670</F3207>
<C080>
<F3036>DUMMY B.V.</F3036>
</C080>
<C059>
<F3042>VERLENGDE VOORBEELDWEG 123</F3042>
</C059>
</NAD>
</SG11>
<SG11>
<NAD>
<F3035>CZ</F3035>
<F3164>AMSTERDAM</F3164>
<F3251>1234 AB</F3251>
<F3207>670</F3207>
<C080>
<F3036>DUMMY WIRE & CABLE B.V.</F3036>
</C080>
<C059>
<F3042>INDUSTRIEGEBIED: 1234</F3042>
<F3042>VOORBEELDWEG 10</F3042>
</C059>
</NAD>
<SG12>
<CTA>
<F3139>IC</F3139>
<C056>
<F3412>JANE DOE</F3412>
</C056>
</CTA>
<COM>
<C076>
<F3148>+31(0)12 3456789</F3148>
<F3155>TE</F3155>
</C076>
</COM>
</SG12>
</SG11>
<SG11>
<NAD>
<F3035>SF</F3035>
<F3164>AMSTERDAM</F3164>
<F3251>1234 AB</F3251>
<F3207>670</F3207>
<C080>
<F3036>DUMMY WIRE & CABLE B.V.</F3036>
</C080>
<C059>
<F3042>INDUSTRIEGEBIED: 1234</F3042>
<F3042>VOORBEELDWEG 10</F3042>
</C059>
</NAD>
<SG12>
<CTA>
<F3139>IC</F3139>
<C056>
<F3412>JANE DOE</F3412>
</C056>
</CTA>
<COM>
<C076>
<F3148>+31(0)12 3456789</F3148>
<F3155>TE</F3155>
</C076>
</COM>
</SG12>
</SG11>
<SG11>
<NAD>
<F3035>FW</F3035>
<F3251>1234 AB</F3251>
<F3207>670</F3207>
<C080>
<F3036>LOGISTICS B.V.</F3036>
</C080>
</NAD>
</SG11>
<SG18>
<GID>
<F1496>1</F1496>
<C213>
<F7224>1</F7224>
<F7065>E827</F7065>
<F3055>9</F3055>
</C213>
</GID>
<HAN>
<C524>
<F4079>UST</F4079>
<F3055>9</F3055>
</C524>
</HAN>
<SG20>
<MEA>
<F6311>AAE</F6311>
<C502>
<F6313>G</F6313>
</C502>
<C174>
<F6411>KGM</F6411>
<F6314>24</F6314>
</C174>
</MEA>
</SG20>
<SG20>
<MEA>
<F6311>AAE</F6311>
<C502>
<F6313>GMC</F6313>
</C502>
<C174>
<F6411>MTQ</F6411>
<F6314>80</F6314>
</C174>
</MEA>
</SG20>
<SG21>
<DIM>
<F6145>1</F6145>
<C211>
<F6411>MTR</F6411>
<F6168>41</F6168>
<F6140>41</F6140>
<F6008>48</F6008>
</C211>
</DIM>
</SG21>
<SG23>
<PCI>
<F4233>33E</F4233>
</PCI>
<GIN>
<F7405>BJ</F7405>
<C208>
<F7402>00387142520086154710</F7402>
</C208>
</GIN>
</SG23>
</SG18>
</Message_IFTMIN>